A successful helium testing campaign for ITER’s first production cryopump has demonstrated strong pumping performance and provided valuable experience with the equipment, instrumentation and procedures that will be used during commissioning. An ultra-high vacuum measuring 10⁻⁶ pascal must be created inside the vacuum vessel before a plasma can be generated.
One of the stars of this process, a customized cryopump developed through two decades of research, has now shown it can efficiently evacuate helium from a test tank and achieve the target vacuum levels. “The results are a win for all of us,” says Alessandra Iannetti, ITER’s vacuum delivery coordinator. “It’s also an important step towards operating the tokamak vacuum systems because we’re not just testing equipment and instrumentation, we’re learning how to work together and refining procedures that, until now, have largely existed on paper.”
The vacuum required in the ITER plasma chamber will be created in two steps. First, mechanical pumps, known as “roughing pumps,” suck air molecules out of the chamber, taking the pressure down from 10⁵ pascals to 10 pascal. Then, the specialized cryopumps reduce the pressure to the required base operating level of 10⁻⁶ pascal through “cryosorption”: the pumps are cooled to 4.5 K (about −269 °C), and at these extremely low temperatures, residual gas particles lose energy and are trapped as they come into contact with the activated charcoal in the cryopanels.
The cryopumps will also perform a critical function during plasma operations by removing exhaust gases, including the helium “ash” produced by fusion reactions. In total, there will be eight main cryopumps serving the ITER tokamak: six to create and maintain vacuum conditions in the vacuum vessel and two installed on the cryostat to provide the vacuum that thermally insulates the magnet system.
To confirm the cryopumps can perform at the necessary levels, ITER built a cryopump test facility and ran cold tests on a pre-production cryopump in 2025. Testing of the first production pump was conducted from 21 to 27 October 2026 using a 15-cubic-metre test tank. Pumping tests were performed with helium and a mixture of helium, hydrogen and neon. The pump reached the target of 10⁻⁶ pascal while demonstrating a helium pumping capacity nearly 50% higher than achieved on the pre-production unit tested last year.
The campaign also provided an opportunity to test several auxiliary systems, including control software and procedures to isolate the pump for regeneration. The team also gained experience with the residual gas analyzer and specialized vacuum instrumentation. In 2027, a second production cryopump will be tested for its ability to evacuate hydrogen. All eight pumps will then be kept in protected storage until their installation in the tokamak, scheduled to begin in 2029.
"The experience we have gained from this round of testing on the production cryopump is a positive step towards commissioning,” says Liam Worth, ITER Vacuum Systems Project Leader. “The helium results are encouraging, and the campaign has provided valuable information that will help us prepare for the next phase of testing with hydrogen in 2027.”